The Naval Constructor: A Vade Mecum of Ship Design for Students, Naval Architects, Shipbuilders and Owners, Marine Superintendents, Engineers and DraughtsmenD. Van Nostrand Company; [etc., etc. ], 1914 - 819 sivua |
Kirjan sisältä
Tulokset 6 - 10 kokonaismäärästä 56
Sivu 84
... allowance for erections under clause 11 will be therefore of 24 ins . , or 91⁄2 ins . We have therefore : Deduct . Amount deducted from freeboard for ex- cess of sheer . . . . in . 11 Amount deducted from the freeboard for erections ...
... allowance for erections under clause 11 will be therefore of 24 ins . , or 91⁄2 ins . We have therefore : Deduct . Amount deducted from freeboard for ex- cess of sheer . . . . in . 11 Amount deducted from the freeboard for erections ...
Sivu 87
... allowance on this account should not exceed that given in the following table : MOULDED DEPTH OF VESSEL TO MAIN - DECK . ALLOWANCE . Inches . Feet . 16 .. 20 . 24 . 28 . 4321 If , however , the scantlings of the bridge - house are in ...
... allowance on this account should not exceed that given in the following table : MOULDED DEPTH OF VESSEL TO MAIN - DECK . ALLOWANCE . Inches . Feet . 16 .. 20 . 24 . 28 . 4321 If , however , the scantlings of the bridge - house are in ...
Sivu 89
... allowance is to be made under sub - para . ( a ) , when the erections extend over less than of the length ; but in all vessels when the erections cover or more of the length , and in spar- and awning - decked vessels the allow- ance is ...
... allowance is to be made under sub - para . ( a ) , when the erections extend over less than of the length ; but in all vessels when the erections cover or more of the length , and in spar- and awning - decked vessels the allow- ance is ...
Sivu 90
... allowance should be proportioned between that allowed for erections the length under para . 14 and that allowed for erections covering of the length under para . 11 , and the corrections for length and sheer should be included in ...
... allowance should be proportioned between that allowed for erections the length under para . 14 and that allowed for erections covering of the length under para . 11 , and the corrections for length and sheer should be included in ...
Sivu 92
... allowance for erections on deck to vessels with top - gallant forecastles having long poops or raised quarter- decks connected with bridge - houses is not to be used without modification , unless the strength of the bulkhead at the ...
... allowance for erections on deck to vessels with top - gallant forecastles having long poops or raised quarter- decks connected with bridge - houses is not to be used without modification , unless the strength of the bulkhead at the ...
Muita painoksia - Näytä kaikki
The Naval Constructor: A Vade Mecum of Ship Design for Students, Naval ... George Simpson Esikatselu ei käytettävissä - 2017 |
Yleiset termit ja lausekkeet
anchor angle Awning Deck beam bending bending moment block block coefficient bolts bridge-house bulkheads calculated carry cent centre of gravity CHAIN COEFFICIENT OF FINENESS coko correction for length correction for sheer cubic feet curve davits Deck at Side deck stringer Deck Vessels deduct Diam diameter dimensions displacement distance draught equal First-class Sea-going fitted Flanges foot forecastle frame Freeboard for First-class freeboards in Tables friction half-breadth HEIGHT OF FREEBOARD inertia iron keel keelson KNOTS less Lloyd's load Main Deck Measured from Top MILLIMETRES moment of inertia moulded depth Orlop deck Pipe plate poop pounds RADIUS OF GYRATION RESERVE BUOYANCY riveted rudder rule scantlings screw shackle sheave shelter deck ship space Spar Deck speed square inch Steam Vessels steamers steel stem stern sternpost strake strength stress THICKNESS IN TWENTIETHS tonnage tons upper deck water line white light wire rope wood
Suositut otteet
Sivu 572 - Nothing in these rules shall interfere with the operation of any special rules made by the government of any nation with respect to additional station and signal lights for two or more ships of war or for vessels sailing under convoy...
Sivu 568 - A vessel of one hundred and fifty feet or upwards in length, when at anchor, shall carry in the forward part of the vessel, at a height of not less than twenty and not exceeding forty feet above the hull, one such light, and at or near the stern of the vessel, and at such a height that it shall be not less than fifteen feet lower than the forward light, another such light.
Sivu 567 - ... shall be exhibited, in sufficient time to prevent collision, so that the green light shall not be seen on the port side nor the red light on the starboard side.
Sivu 571 - ... use, and shall flash or show them at short intervals, to indicate the direction in which they are heading, but the green light shall not be shown on the port side, nor the red light on the starboard side. A pilot vessel of such a class as to be obliged to go alongside of a...
Sivu 569 - ... abaft the beam on the starboard side, and of such a character as to be visible at a distance ot at least 2 miles. (c) On the port side a red...
Sivu 567 - Pilot vessels, when engaged on their station on pilotage duty, shall not show the lights required for other vessels, but shall carry a white light at the masthead, visible all round the horizon, and shall also exhibit a flare-up light or flare-up lights at short intervals, which shall never exceed fifteen minutes.
Sivu 566 - The highest and lowest of these lights shall be red, and the middle light shall be white, and they shall be of such a character as to be visible all around the horizon, at a distance of at least two miles.
Sivu 568 - The white light required to be shown by this article may be fixed and carried in a lantern, but in such case the lantern shall be so constructed, fitted, and screened that it shall throw...
Sivu 565 - ... feet above or below such lights, if the length of the tow measuring from the stern of the towing vessel to the stern of the last vessel towed exceeds 600 feet.
Sivu 565 - These two lights shall be so placed in line with the keel that one shall be at least 15 feet higher than the other and in such a position with reference to each other that the lower light shall be forward of the upper one. The vertical distance between these lights shall be less than the horizontal distance.